TC2290 Ext FX switching
Hi,
I am absolutely new to the
group and more a guitar player than a loop-man.
I've been searching a while for
a way to switch the ext. FX loops on my TC2290 (everybody said this wasn't
possible) but meanwhile I found a SysEx Data pdf-file on the TC homepage and I
know that one of you people (Mr.Zvonar) has made it happen.
But I don't understand the half
of this stuff.
I already found out that to
switch the FX loops I need a "SysEx" Keycode command that is defined as
follow:
1Bit SysEx
on F1
2Bit
Manuf.ID 33
3Bit
DeviceID 02 (my unit is set to DeviceID
2)
4Bit
DataType 05 (which means keycode
commands)
5Bit
MSB
6Bit
LSB
7Bit
Value
8Bit SysExEnd
7F
I have problems with Bit 5 to
7! I know that the keys have Keycodes from 1 to 199 implemented. When I want to
switch the FX on the unit itself I have to press CHANGE (KC 60) and then number
1 for loop1 or number 2 for loop2,etc..
My TC reacts to Midi
ProgChanges and sometimes it reacts to SysEx Data (I messed around with this and
sometimes got reaction), but I am too stupid to get it
right.
Can anybody help me on
this?
Thanx,
Stefan