RE: EDP Brothersync...?
>can't you just set synch=in on the "slave" boxes?
yes, that works!
Its not quite according to the intention, since Sync=in also opens to 
create little correction jumps at the loop end. But I just tried it 
and it does what we expect: Since the two machines run at the same 
speed on sample clock level, that sync correction happens once and 
then never more.
So I realize its actually a way to test whether two units really sync 
up on sample clock level (which not all do, unfortunatelly... the 
tolerances changed over the years...)
>
>>...
>>  so....
>>  hey Matthias
>>  would it be possible to modify the "brother hub" with a
>>  couple of diodes so that one EDP could always be master? (so
>>  that any "slave" EDPs only get the cycle end from one "master" EDP) 
>>
>>  andy butler
>>
-- 
          ---> http://Matthias.Grob.org