Looper's Delight Archive Top (Search)
Date Index
Thread Index
Author Index
Looper's Delight Home
Mailing List Info

[Date Prev][Date Next]   [Thread Prev][Thread Next]   [Date Index][Thread Index][Author Index]

RE: Solution for Stereo EDPs and Timing Drift: Three Critical Parameter Settings



I don't think so...this is why my new EDPs wouldn't sync right out of
the box.

Kris


-----Original Message-----
From: David Kirkdorffer [mailto:vze2ncsr@verizon.net] 
Sent: Thursday, September 16, 2004 8:43 AM
To: Loopers-Delight@loopers-delight.com
Subject: Re: Solution for Stereo EDPs and Timing Drift: Three Critical
Parameter Settings


Kim -

The default setting on the Loop IV is Threshold = 0 --- yes?


----- Original Message ----- 
From: "Kim Flint" <kflint@loopers-delight.com>
To: <Loopers-Delight@loopers-delight.com>
Sent: Thursday, September 16, 2004 2:06 AM
Subject: Re: Solution for Stereo EDPs and Timing Drift: Three Critical
Parameter Settings


> Hi-
>
> Just to emphasize since others seem to have this issue: for stereo
Echoplex
> units, Threshold recording will cause the loops to go out of sync. You
need
> to set Threshold = 0.
>
> The threshold parameter sets an audio threshold so that loop recording
does
> not start until you begin playing. With stereo and threshold on, both
units
> will begin in a mode waiting for the audio. The audio will always 
> arrive slightly different between the two units, so it will cross the 
> threshold
at
> slightly different times to start the recording. The loops will 
> therefore usually end up being slightly different lengths, and they 
> drift out of sync. We tried for some time to think of a way to make 
> this work but never found it.
>
> kim
>
> At 07:26 AM 9/10/2004, Krispen Hartung wrote:
> >After struggling with getting my two new EDPs to sync in stereo via 
> >BrotherSync, Kim Flint came in to save my Friday. My final parameter 
> >settings are below, and I've noted the setting that did the trick in 
> >addition to what is recommended in the manual.
>
> >Threshold=0 (THIRD CRITICAL SETTING, NOT IN MANUAL...NEEDS TO BE SET 
> >TO
0)
>
> ______________________________________________________________________
> Kim Flint                     | Looper's Delight
> kflint@loopers-delight.com    | http://www.loopers-delight.com
>